5. The EPSON RC+ 5.0 GUI
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 79
Tools: Robot Manager: Control Panel Page
The Control Panel page contains buttons for basic robot operations, such as turning motors
on/off and homing the robot. It also shows status for Emergency Stop, Safeguard, Motors,
and Power.
Status Indicators
Indicator Description
Emergency Stop
Indicates if Emergency Stop has occurred. Once an Emergency
Stop occurs, you must execute a Reset to clear it.
Safeguard
Indicates whether the Safeguard input is on or off.
Motors
Indicates whether the robot motors are on or off.
Power
Indicates whether the robot motor power is high or low.
Controls Description
MOTOR ON
Turns on all robot motors for the robot. You will be prompted to
confirm this operation.
MOTOR OFF
Turns off all robot motors for the robot.
POWER LOW
Puts the robot servo system in low power mode.
POWER HIGH
Puts the robot servo system in high power mode.
J1 to J4 checkboxes
You can free one or more joints using the checkboxes. These will
be disabled for 6-axis robots.
Free All
Click this button to free all joints from servo control.
Lock All
Click this button to lock all joints under servo control.
Reset button Resets the robot servo system and Emergency Stop condition.
Home button Moves the robot to the position specified with the HomeSet
command.