5. The EPSON RC+ 5.0 GUI
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 133
Setup: Controller: RS232 Pages
There is one page for each RS232 port installed in the controller. If there are no RS232
ports installed in the controller, then no RS232 selections are visible in the tree.
To configure an RS-232 port
1. Select Controller from the Setup Menu and select the page for the RS232 port you want
to configure.
2. Change the settings as desired. You can also click the
Defaults button to use default
settings.
3. Click
Apply to save the new settings and click Close.
Setup: Controller: TCP/IP Pages
You can configure TCP/IP settings for the robot controller in a SPEL+ program using the
SetNet command. You can also configure settings from the TCP/IP tab on the Setup |
Controller dialog.
To configure a TCP/IP port
1. Select Controller from the Setup Menu and select the page for the TCP/IP port you
want to configure.
2. Enter the host name or IP address for the controller or PC that you want this controller
to communicate with.
The controller does not support DNS, so you must specify an IP address for the host
you are communicating with. You cannot specify a name for the host.
3. Enter the TCP/IP port number. This must be the same port number that is used on the
host device. It must be different from any of the other TCP/IP port numbers used for
the other TCP/IP ports.
)
NOTE