11. Remote Control
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 251
11.7 Remote Inputs
Remote inputs are used to control the Manipulators and start programs. Certain conditions
must be met before inputs are enabled, as shown in the table below.
To accept external remote inputs, assign the remote function and set remote to the control
device. When external remote input is available , “AutoMode output” turns ON.
Except SelProg”, the signals execute each function when the signal starts in input
acceptance condition. The function executes automatically. Therefore, no special
programming is needed.
When an error occurs, you must execute a Resetto clear the error condition before any
other remote input commands can be executed. Use the Error outputand Reset input
to monitor the error status and clear error conditions from the remote device.
Name Initial Description
Input Acceptance Condition (*1)
Start 0
Executes function selected at SelProg.(*2
Ready output ON
Error output OFF
EStopOn output
OFF
SafeguardOn output
OFF
Pause
input OFF
Stop input OFF
SelProg1
SelProg2
SelProg4
1
2
3
Specifies the executing Main function
number. (*2)
Stop 4
Stops all tasks and commands.
Pause 5
Pauses all tasks. (*3)
Running output ON
Continue 6
Continues the paused task.
Paused output ON
Pause input OFF
Stop input OFF
Reset 7
Resets emergency stop and error. (*4)
Ready output ON
SetMotorsOn NA
Turns ON robot motors. (*5)
Ready output ON
EStopOn output OFF
SafeguardOn output
OFF
SetMotorsOff input OFF
SetMotorsOff NA
Turns OFF robot motors.
Ready output ON
Home NA
Moves the Robot Arm to the home
position defined by the user.
Ready output ON
Error output OFF
EStopOn output
OFF
SafeguardOn output
OFF
MotorsOn output ON
Pause
input OFF
Stop input OFF
ForcePowerLow
(*6)
NA
Stops all tasks and commands.
Sets the motor power at Low.
The status is Low power mode while
the input is ON even executing Power
High command.
Any time
This input is acceptable even
AutoMode output is OFF.
(*1) “AutoMode output” ON is omitted from the table. This is an input acceptance condition for all functions.
(*2) “Start input” executes Function specified by the “SelPlog1, 2, 4, and 3bits.
NOTE