11. Remote Control
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 249
11.2 Remote Control Input Output Configuration
This is the procedure to assign the remote functions to the I/O.
1. Select Controller from the Setup Menu and select the Remote Control Inputs or
Remote Control Outputs page.
2. For each input or output you want to use for remote control, click on the Input # or
Output # cell for the desired signal, then click the arrow and select a bit number.
3. Click OK to save the new settings.
For details of dialog setting, refer to 5.12.2 Controller Command (Setup Menu).
11.3 Control Device Configuration
This is the procedure to set the control device to “Remote I/O”.
1. Set the controller control device to Remote. Select Controller from the Run Menu,
click on Configuration in the tree on the left, then select “Remote I/O” from the Control
Device dropdown list.
2. Click Apply to save the new setting and the click Close.
For details of setting, refer to 5.12.2 Controller Command (Setup Menu).
Comentários a estes Manuais