5. The EPSON RC+ 5.0 GUI
132 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4
Setup: Controller: Remote: RS232
Use this page to configure the Remote RS232.
When the Remote RS-232C port is not installed to the Controller, RS232 is not shown in
the tree.
These settings are necessary when the control device is “Remote Ethernet”, or when the
operator acquires the value using the Remote Ethernet while the control device is not
“Remote Ethernet”.
Item Description
Port
Specify a port No. used for remote RS232 communication.
For example, RS-232C port of the Controller is allotted to the
Remote RS232 connection in the above dialog.
Specify the port No. that is not used for other RS-232C
communication.
RS-232C port setting is the value specified at Controller | RS-232C |
Specified port No.
Password
Specify a password for client authentication to connect.
Authentication is accomplished with the Login command.
Use only for
monitoring
Select to acquire the value using Remote Ethernet, if Control device
is not Remote Ethernet.
Close
Close the dialog.
Apply
Save the current changes.
Restore
Revert back to the previous settings.
Defaults
Click this button to set the Remote RS232 default settings.
Default setting
RS-232C port No. : 1
Password : No setting
Use for monitoring : No
CAUTION
If you set “0” in the [Timeout] textbox of the specified RC-232C port, then the
time out duration is infinite. In this case, the task(s) continue to execute even
without the communication from client. This means the robot may keep moving
and cause unexpected damage. Ensure that tasks will be stopped appropriately
in your system.