5. The EPSON RC+ 5.0 GUI
90 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4
Using the Local Wizard to teach a three point local
1. Open the Robot Manager and click on Locals to show the Locals page.
2. Click the
Local Wizard button. You will see the dialog shown below.
3. Select the local number you want to define. For
How many points will be used, select
3 - Origin, X, Y. Since this is a three point local, you will teach the origin of the new
coordinate system, and then teach one point anywhere along the X axis and one point
anywhere along the Y axis. Select which axis will be used to align the coordinate
system. For example, if you select X, then the new coordinate system X axis will be
aligned to the X axis point that you will teach in a later step. The Y axis point will be
used to determine tilt. Click the
Next button.