8. Simulator
Enable the Simulator in controller
From the [Setup]-[Controller]-[Simulator], check the [Enable Simulator] check box to
enable the simulator function.
After checking the check box, click the <Apply> button and then click the <Close> button.
If collision with the simulator object is detected during a Jog motion or a robot motion
command execution when the Simulator is enabled, the Manipulator stops operation and a
Warning occurs.
To avoid collision with peripherals by using the Simulator, set 15 mm or greater margins to
the simulator object.
Function restrictions when connected with controller
- Pallets cannot be displayed.
- You cannot change the robot from the Simulator window.
- You cannot select and move the robot arms in the Simulator window, except during
the controller Dry run.
- When the robot configured in the controller is not supported in the Simulator, a
warning message is displayed when the Simulator window is opened, and the
object list and the robot in 3D window are not displayed.
- The [Record/Playback] functions are not available.
Operator Window
When you enable the Simulator, the <Simulator> button is added to the Operator Window.
When you click on the <Simulator> button, the 3D display window appears.