2. Safety
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 11
2. Safety
2.1 Overview
This chapter explains the important safety requirements for robotic systems using EPSON
RC+ 5.0 and the robot Controller.
Installation of robots and robotic equipment should only be performed by qualified
personnel in accordance with national and local codes. Please read and understand this
entire chapter before using your EPSON RC+ 5.0 system.
Remember that safety is the most important consideration when designing and operating
any robotic system.
WARNING
This sym
bol indicates that a danger of possible serious injury or
death exists if the associated instructions are not followed
properly.
WARNING
This symbol indicates that a danger of possible harm to people
caused by electric shock exists if the associated instructions are
not followed properly.
CAUTION
This symbol indicates that a danger of possible harm to people or
physical damage to equipment and facilities exists if the
associated instructions are not followed properly.
2.2 Definitions
2.2.1 Robot Power
The status of robot power is explained below in terms of restriction to operation:
Operation-prohibited status: Robot cannot be operated.
Restricted (low power) status: Robot can operate at low speed and low torque.
Unrestricted (high power) status: Robot can operate without restriction.
The robot will not operate regardless of the control actions taken by the operator when in
the operation-prohibited state. During operation, when the safeguard circuit opens, the
system will switch to operation-prohibited state.
The robot will operate at low speed and torque in the restricted state (low power). In the
unrestricted state (high power), the robot will operate at the programmed speed and torque.
In the event that the robot should make an unexpected movement, the restricted state (low
power) decreases operating speed allowing the operator to avoid danger. The torque is
also decreased to minimize serious injury to the operator should one be struck by the robot.
The maximum values of the decreased speed and torque are set according to the robot used
and cannot be changed by the user.
As a safety precaution the initial power state of the robot will be set to either the restricted
(low power) state or the operation-prohibited state. The system will not change to the
unrestricted (high power) state if the appropriate procedures are not followed.
When the system is in restricted (low power) state or operation-prohibited state, a single
failure will not cause a runaway action that surpasses the assigned speed or torque decrease.
This is due to the multi-protect circuit and mutual monitoring circuit in the control system.