5. The EPSON RC+ 5.0 GUI
114 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4
Restore Controller
Use Restore Controller to load controller settings from previously saved backup data. You
cannot restore the controller data while tasks are running. If you attempt to do so, an error
message will be displayed.
To restore controller configuration:
1. Select Tools | Controller.
2. Click on the
Restore Controller button to open the Browse For Folder dialog.
3. Select the drive and folder where the information is stored. Controller backup
information is stored in a folder that is named “B” plus the controller serial number
followed by the date / time.
You can also select a folder containing export controller status information.
Export controller status is stored in a folder that is named “S” plus the controller serial
number followed by the date / time.
4. Click
OK to display the dialog to select the restore data.
Robot name, serial #, calibration Checkbox
This checkbox allows you to restore the robot name, robot serial number, Hofs data,
and CalPls data. Make sure that the correct Hofs data is restored. If the wrong Hofs
data is restored, the robot may move to wrong positions.
The default setting is unchecked.
Project Checkbox
This checkbox allows you to restore the files related to projects.
The default setting is unchecked.
When the project is restored, all the values of Global Preserve variables are restored.
For details about Global Preserve variable backup, refer to
5.10.10 Display Variables
Command (Run Menu)
.
When the version of the connected RC180 controller firmware is Ver.1.0.*.*, this
dialog does not appear. Robot name, serial number, and calibration data is always
restored.
The project is not restored.
)
NOTE
)
NOTE