11. Remote Control
EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 267
For the details of the dialog setting, refer to the section 5.12.2 Controller (Setup menu) -
Setup: Controller: Setup.
Set the remote control available by the following procedure.
(1) Open RS-232C port that is connected from client equipment to the specified port in the
Remote RS232 of the Controller, using the communication parameter specified in the
RS-232C port setting.
(2) Send the remote start command (EOT).
(3) Specify the password set in the Remote RS232 to the parameter and send the Login
command.
(4) Client equipment has to wait until Auto (GetStatus command response) is ON, before
execution of remote command.
(5) Now remote command will be accepted.
Each command executes the function when the input acceptance condition is satisfied.
Program debug from EPSON RC+ 5.0 development environment is capable as follows.
(1) Build a program as usual.
(2) Open the Run window and Click the RS232 Enable button.
When you only acquire the value using the Remote RS232 control, the RS232 Enable
button is not displayed. Click the Start button of the device specified as the control
device.
(3) Now remote command will be accepted.
Brakepoint setting and output to the Run window is available.
After Login, if no command is send within the timeout duration of the RS-232C, the
timeout error will be returned. In this case, re-execute from sending remote start command.
If error occurs, execute the Reset command to clear the error condition before executing
the operation command. To clear the error condition from external equipment by
monitoring, use the “GetStatus” and “Reset” command.