Rev. A Features and General Specifications 1-23
TM-T88 Series Technical Manual
Note: A macro can be executed r times (r specifies the number of times to execute the macro)
within the specified definition range. The macro can be executed continuously or can be
executed by pressing the button. If the macro is executed by pressing the FEED button, the
PAPER LED blinks to indicate the macro execution ready state.
Figure 1-14 Panel Button and Indicators
Self-test
The printer has a self-test function that checks the following:
❏ Control circuit functions
❏ Printer mechanisms
❏ Print quality
❏ Control Software version
❏ DIP switch settings.
See Chapter 4 for instructions on running a self-test.
Hexadecimal Dump
Hexadecimal Dumping Function
This function prints the data transmitted from the host computer in hexadecimal numbers and
in their corresponding characters.
Performing a Hexadecimal Dump
Open the cover and turn the power on while pressing the FEED button; then close the cover.
The printer first prints "Hexadecimal Dump" on paper roll and prints the received print data
in hexadecimal numbers and in its corresponding characters.
ERROR
POWER
PAPER
OUT
FEED