Epson SED 1520 Series Especificações Página 37

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 54
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 36
S1D15300 Series
Rev.1.4 EPSON 5–25
When the built-in power supply is not used immediately after the main power is turned on:
Turn on the power save mode (multiple commands) *7
Turn VDD and VSS power on with
RES terminal being set to LOW.
Wait until the power supply is stabilized.
Turn on the initial setup mode (Default) *1
Initial setup is complete
Function select through the commands (user setup)
LCD bias set *2
ADC select *3
Common output mode select *4
Function select through the command (user setup)
Electronic volume *5
Turn off the power save mode *6
Function select through the command (user setup)
Power control set * 7
Cancel the reset mode (RES terminal = HIGH)
Operations ranging from turning off of
the power save mode through the
power control set must be completed
within 5 ms.
The power save mode must be turned
on within 5 ms from powering on.
* This duration of 5 ms depends on the panel characteristics as well as capacity of the capacitor concerned. Check them on the actual system.
Notes: *1: Refer to the “Reset Circuit” in the Function Description.
*2: Refer to the “LCD Bias Set” in the Command Description (11).
*3: Refer to the “ADC Select” in the Command Description (8).
*4: Refer to the “Output State Register Set” in the Command Description (15)
*5: Refer to the “Supply Circuit” in the Function Description and the “Electronic Volume Register Set” in the Command Description
(17).
*6: Refer to the “Supply Circuit” in the Function Description and the “Power Control Set” in the Command Description (16).
*7: You can select either the sleep mode or standby mode for the power save mode. Refer to the “Power Save (Multiple Commands)”
in the Command Description (19).
Vista de página 36