Ethernet IV Connect-it™ Module Installation
Appendix H Revision C: 8/30/2004
2
TM-U675
Switch Bank 1
All Various Off
Switch Bank 2
2-1 Condition for BUSY On
2-2 Reserved Off
2-3 Characters per line User
2-4 TM-U375 print width User
2-5 Reserved Off
2-6 Reserved Off
2-7 Reserved Off
2-8 Pin #31 reset On
TM-H6000II
Switch Bank 1
All Various Off
Switch Bank 2
2-1 Condition for BUSY On
2-2 Reserved Off
2-3 Print density User
2-4 Print density User
2-5 Reserved Off
2-6 Reserved Off
2-7 Reserved Off
2-8 Pin #31 reset On
TM-U220B (US)
Switch Bank 1
1-8 Condition for BUSY On
All others Various Off
Switch Bank 2
2-4 Pin #31 reset On
All others Various Off
TM-U220B (STD)
TM-U230B/D
Switch Bank 1
1-2 Condition for BUSY On
All others Various Off
Switch Bank 2
2-1 Characters per line User
2-2 Autocutter User
2-3 Reserved Off
2-4 Pin #31 reset On
2-5 Paper out blink patter User
2-6 Reserved Off
2-7 Reserved Off
2-8 Internal buzzer User
Installation Steps
1. Disconnect power and connected other cables from the EPSON printer, and remove the printer
DIPswitch cover plate.
2. Remove the existing interface board from the printer by unscrewing 2 screws.
3. Properly align and push the new module into the printer. Fasten the two mounting screws
through the faceplate of the new interface.
4. Set DIPswitches as necessary; then attach the access cover.
5. Connect the power cable to the printer and apply power.
6. Run a configuration report. This shows that the printer, module, and firmware are all installed
and operating correctly and shows how the communication parameters are set.
Running a Configuration Report
There are three different ways to generate a configuration report with the Ethernet-IV. The
first is to have SW-1 (on the EEI-IV) on when the printer is powered on. The second is to
click on the ‘Test’ button in the eeiutil.exe program. The third is to open the cover, press
feed and then close the cover quickly.
Configuring the Interface
Each EEI module has a 'Base' Ethernet Address programmed into the Serial EPROM. A unique
Ethernet Address and Serial Number are programmed into the EEPROM at the factory, and cannot
be changed. Labels with both the Ethernet address and serial number are affixed to the module.
These numbers are important when configuring the EEI - It is advisable to make a note of these
values in a secure place.
Configuration of this module should only be attempted by a qualified network administrator.
Configuration
Use the supplied printer discovery program, EEI Configuration Program (ver. 1.3 or greater). Insert
the floppy disk into the drive and run x:\eeiutil.exe (where x is the drive letter of your 3.5” floppy
drive). The program will discover all Epson Ethernet printers on your network and allow you to test
and reconfigure them.
Switch Bank 1
1-8 Condition for BUSY On
All others Various Off
Switch Bank 2
2-8 Pin #31 reset On
All others Various Off
Comentários a estes Manuais