Rev. A Specifications 1-7
TM-J8000/J8000P Technical Manual
Confidential
DIP switches
Serial interface model
(BPS: Bits Per Second)
Note: Changes in DIP switch settings (excluding switches 2-7 and 2-8, interface reset signals) are recognized only
when the printer power is turned on or when the printer is reset by using the interface. If the DIP switch
setting is changed after the printer power is turned on, the change does not take effect until the printer is
turned on again or is reset.
Table 1-8 DIP switch 1
SW 1 Function ON OFF
1 Data reception error Ignored Prints “?”
2 Receive buffer capacity 45 bytes 4K bytes
3 Handshaking XON/XOFF DTR/DSR
4 Word length 7 bits 8 bits
5 Parity check Yes No
6 Parity selection Even Odd
7 Transmission speed selection
Refer to Table 1-9
8
Table 1-9 Transmission speed
Transmission Speed[BPS] SW 1-7 SW 1-8
2400 ON ON
4800 OFF ON
9600 ON OFF
19200 OFF OFF
Table1-10 DIP switch 2
SW 2 Function ON OFF
1 Handshaking (BUSY condition) Receive buffer full Offline or
receive buffer full
2 Customer display (DM-D) connection Connected Not connected
3 Head rank switching Rank B Rank A
4 Power switch mode setting Power switch fixing
mode
Normal mode
5 Interlocking operation with IM Interlocking Not interlocking
6 Internal use — Fixed to OFF
7 I/F pin 6 reset signal Enabled Disabled
8 I/F pin 25 reset signal Enabled Disabled
Comentários a estes Manuais