3.2.4 Removing the B034 PSB/PSE Power Supply Board
1. Remove the bottom plate. (Refer to Section 3.2.2.)
2.
Remove 3 CBP-tite (M3 × 12) screws.
3. Disconnect the 2 cables on the board, and then remove the board.
CAUTION
Turn the main unit over onto a soft cloth so that the glass will not be damaged.
ASSEMBLY POINT
When you connect the cable to connector CN2 of the B034 PSB/PSE board, align the red stripe on
the cable with pin 1 of CN2.
CBP-tite (M3x12)
B034 PSB/PSE Board
Figure 3-5. Removing the B034 PSB/PSE Board
Disassembly and Assembly GT-5000 / Action Scanner II Service Manual
3-6 Rev. A