SPECIFICATIONS FOR LIQUID CRYSTAL DISPLAY MODULE
PACIFIC DISPLAY DEVICES 04.25.2012 16
4. RELIABILITY
storage
Endurance test applying the high storage
temperature for a long time.
Endurance test applying the low storage
temperature for a long time.
operation
Endurance test applying the electric stress
(Voltage & Current) and the thermal stress to
the element for a long time.
200 hrs
------
Low temperature
operation
Endurance test applying the electric stress
under low temperature for a long time.
High temperature /
Humidity storage
Endurance test applying the high temperature
and high humidity storage for a long time.
Humidity operation
Endurance test applying the electric stress
(Voltage & Current) and temperature / humidity
stress to the element for a long time.
96 hrs
JIS-C5023
Endurance test applying the low and high
temperature cycle.
10 cycles
------
Endurance test applying the vibration during
transportation and using.
22∼500Hz → 1.5G
JIS-C5025
JIS-C7022-A-10
Constructional and mechanical endurance test
applying the shock during transportation.
wave 1l msedc
3 times of each direction
Atmospheric
pressure test
Endurance test applying the atmospheric
pressure during transportation by air.
Endurance test applying the electric stress to the
terminal.
CS=100 pF
3015.1
∗∗∗ Supply voltage for logic system = VDD. Supply voltage for LCD system = Operating voltage at 25°C
■ LCD Panel Service Life
Definition of panel service life
• 100,000 hours minimum at 25° C ±10%
• Contrast becomes 30% of initial value
• Current consumption becomes three times higher than initial value
• Remarkable alignment deterioration occurs in LCD cell layer
• Unusual operation occurs in display functions
5min.