Transparency Unit (B813202)
General
Reliability MCBF 100,000 cycles
Readable area 11.4
× 16.5 inches (290 × 420 mm)
Dimensions Width: 12.8 inches (324 mm)
Depth: 21.3 inches (540 mm)
Height: 3.6 inches (92 mm)
Weight Approximately 11 lb (6 kg)
Electrical Input voltage: 21.6 to 26.4 VDC
4.7 to 5.25 VDC
Rated current: 1.3A
0.3 A
Environmental
Temperature Operating: 41 to 95 °F (5 to 35 °C)
Storage:
−14 to 140 °F (−20 to 60 °C)
Humidity (without
condensation) Operating: 10 to 80%
Storage: 10 to 85%
Automatic Document Feeder (B813212)
General
Paper input/output Load face-up; eject face-down
Paper quantity 100 pages (55 g/m
2
paper, maximum
total thickness under 0.48 inches
[12 mm])
Reliability 100,000 sheets (load/eject MCBF)
Dimensions Width: 23.8 inches (606 mm)
Depth: 19.2 inches (488 mm)
Height: 5.3 inches (134 mm)
Weight Approximately 28.7 lb (13kg)
Electrical
Input voltage 22.8 to 25.2 VDC
4.75 to 5.25 VDC
Input current 24 V: 1.3 A
5 V: 0.3 A
Environmental
Temperature Operating: 50 to 89 °F (10 to 32 °C)
Storage:
−4 to 140 °F (−20 to 60 °C)
Humidity (without
condensation) Operating: 20 to 80%
Storage: 95% or less
IEEE 1394 FireWire Scanner Interface
Card (B808342)
General
Interface type IEEE 1394-1995 compatible
Data transfer
method Half-duplex Data/Strobe differential serial
Synchronization
method Clock synchronization with DS-Link
Encoding/decodingDS-Link
Logic level 3.3 V
Compatible
connectors IEEE 1394-1995 compatible
Power class Power class code 100
No power supply from external sources
Fitted with a repeat function with bus
power
Environmental
Temperature Operating: 41 to 95 °F (5 to 35 °C)
Storage:
−13 to 140 °F (−25 to 60 °C)
Humidity (without
condensation) Operating: 10 to 80%
Storage: 10 to 85%
Lights and Buttons
The scanner has three indicator lights and two buttons on its
control panel. A
] Start button is located beside the
document table. Light status and button functions are
described in the tables that follow.
ERROR light
OPERATE light
READY light
RESET button
P
OPERATE
button