– 27 –
Detecting
signal
+5V
Leaf switch
R2
R1
+5V
R1
R2
+5V
Detecting
signal
R5
Friction
Skew
Tractor
R3
Detecting
signal
R8
R6
Detecting
signal
R9
R4
R7
(3) Paper end Detector
The paper end Detector is located in the paper chute unit. The A/D converter in the CPU detects the presence or
absence of paper.
(4) Release lever switch and lever switch Adjustment
Fig. 2-11 Release lever switch circuit and Adjustment lever switch circuit
Output
Detection
(
V
)
0 No paper
5 Paper present
Control Method
Output Release Adjustment
(
V
)
Lever SW Lever SW
0 Tractor Normal mode
5 Friction Multi-part mode
Control Method
Fig. 2-10Paper end detector circuit