ZVx Test Procedure (ZVM & ZVK)
1127.8500.60 5.13 E-2
5.2.3 Checking the Test Set Specifications
5.2.3.1 Match at PORT1 and PORT2
Test equipment: Calibration Kit ZV-Z32, pair of Test Cables ZV-Z14 (ZVM);
Calibration Kit ZV-Z34, pair of Test Cables ZV-Z15 (ZVK)
Test setup: Description for PORT2 (for PORT1 analogously)
Connect test cable to PORT1,
connect female-female adapter to male end.
Settings on network analyzer:
PRESET
AVG IF BW 100 Hz
Record one-port calibration (OSM) at PORT1 including THRU female-female over
the whole frequency range.
Connect test cables (incl. adapter) with PORT2.
MARKER Measurement frequency
MEAS S11 (S22)
Measurement:
½ Set measurement frequencies according to test record, measure S11 (or S22 for
INPUT B2).
½ Record match values.