Table E-2. Serial interface
X-on/X-off control
Self test
Built-in data buffer
#8143
#8145
yes
no
no
loopback
none
2K
#8148
yes
loopback/
line monitor
218K
X-on/X-off protocol is a system in which the printer transmits a code
to the computer to indicate that it cannot accept more data, and a
second code when it is once more ready.
The loopback self test mode allows direct testing of the functions of
the interface without connecting a computer; line monitor mode is
rather like the FX data dump mode.
Identifying a serial interface board
All Epson interfaces have the EPSON name printed on them. If the
board has an identification code printed on it, it will be a four digit
number beginning with an eight. The number should be one of the
numbers in Table E-3.
If the board has no identification code, or if you are unsure whether
the number you have located is the correct code, check the number of
DIP switches’ on the board against Table E-3.